SAFETY‐KLEENIMMERSIONCLEANERANDCOLDPARTSCLEANER
SafetyDataSheet
AccordingToFederalRegister/Vol.77,No.58/Monday,March26,2012/RulesAndRegulationsAndAccordingToTheHazardousProductsRegulation(February11,2015).
05/23/2022 EN(EnglishUS) 4/14
5.3.AdviceforFirefighters
PrecautionaryMeasuresFire:Exercisecautionwhenfightinganychemicalfire.
FirefightingInstructions:Keepupwind.Removecontainersfromfireareaifthiscanbedonewithoutrisk.Usewatertocool
equipment,surfacesandcontainersexposedtofireandexcessiveheat.
Forlargefiretheuseofunmannedhoseholdersormonitornozzlesmaybeadvantageoustofurtherminimizepersonnelexposure.
Isolatearea,particularlyaroundendsofstoragevessels.Letvessel,tankcarorcontainerburnunlessleakcanbestopped.Withdraw
immediatelyintheeventofarisingsoundfromaventingsafetydevice.Largefirestypicallyrequirespeciallytrainedpersonneland
equipmenttoisolateandextinguishfire.Iftank,railcarortruckisinvolvedinafire,isolatefor1/2mileinalldirections;also,
considerinitialevacuationfor1/2mileinalldirections.
ProtectionDuringFirefighting:Wearfullfire‐fightingturn‐outgear(fullBunkergear)andrespiratoryprotection(SCBA).Donot
enterfireareawithoutproperprotectiveequipment,includingrespiratoryprotection.
HazardousCombustionProducts:Carbonoxides,Nitrogenoxides.Acidhalides.Unidentifiedorganiccompounds.Toxicfumes.
OtherInformation:Donotallowrun‐offfromfirefightingtoenterdrainsorwatercourses.
5.4.ReferencetoOtherSections
RefertoSection9forflammabilityproperties.
SECTION6:ACCIDENTALRELEASEMEASURES
6.1.PersonalPrecautions,ProtectiveEquipmentandEmergencyProcedures
GeneralMeasures:Donotgetineyes,onskin,oronclothing.Donotbreathevapor,mistorspray.Keepawayfromheat,hot
surfaces,sparks,openflames,andotherignitionsources.Usespecialcaretoavoidstaticelectriccharges.Nosmoking.
6.1.1.ForNon‐EmergencyPersonnel
ProtectiveEquipment:Useappropriatepersonalprotectiveequipment(PPE).
EmergencyProcedures:Evacuateunnecessarypersonnel.Stopleakifsafetodoso.
6.1.2.ForEmergencyPersonnel
ProtectiveEquipment:Equipcleanupcrewwithproperprotection.
EmergencyProcedures:Eliminateignitionsourcesfirst,thenventilatethearea.Uponarrivalatthescene,afirstresponderis
expectedtorecognizethepresenceofdangerousgoods,protectoneselfandthepublic,securethearea,andcallfortheassistance
oftrainedpersonnelassoonasconditionspermit.
6.2.EnvironmentalPrecautions
Prevententrytosewersandpublicwaters.
6.3.MethodsandMaterialsforContainmentandCleaningUp
ForContainment:Stopleakifsafetodoso.Asanimmediateprecautionarymeasure,isolatespillorleakareainalldirections.
Containanyspillswithdikesornon‐combustibleabsorbentmaterials.Prevententrytosewersandpublicwaters.
MethodsforCleaningUp:Cleanupspillsimmediatelyanddisposeofwastesafely.Useonlynon‐sparkingtools.Absorband/or
containspillwithinertmaterial.Donottakeupincombustiblematerialsuchas:sawdustorcellulosicmaterial.Transferspilled
materialtoasuitablecontainerfordisposal.Contactcompetentauthoritiesafteraspill.
6.4.ReferencetoOtherSections
SeeSection8forexposurecontrolsandpersonalprotectionandSection13fordisposalconsiderations.
SECTION7:HANDLINGANDSTORAGE
7.1.PrecautionsforSafeHandling
AdditionalHazardsWhenProcessed:Handleemptycontainerswithcarebecauseresidualvaporsareflammable.
PrecautionsforSafeHandling:Donothandleuntilallsafetyprecautionshavebeenreadandunderstood.Obtainspecial
instructionsbeforeuse.Donotgetineyes,onskin,oronclothing.Donotbreathefume,mist,vapors,spray.Useonlynon‐sparking
tools.Takeprecautionarymeasuresagainststaticdischarge.Handleemptycontainerswithcarebecausetheymaystillpresenta
hazard.Washhandsandotherexposedareaswithmildsoapandwaterbeforeeating,drinkingorsmokingandwhenleavingwork.
HygieneMeasures:Handleinaccordancewithgoodindustrialhygieneandsafetyprocedures.
7.2.ConditionsforSafeStorage,IncludingAnyIncompatibilities
TechnicalMeasures:Useexplosion‐proofelectrical,ventilating,andlightingequipment.Takeactiontopreventstaticdischarges.
Groundandbondcontainerandreceivingequipment.Complywithapplicableregulations.
StorageConditions:Storeinadry,coolplace.Keep/Storeawayfromdirectsunlight,extremelyhighorlowtemperaturesand
incompatiblematerials.Keepawayfromignitionsources.Storelockedup/inasecurearea.Storeinawell‐ventilatedplace.Keep
containertightlyclosed.Keepinfireproofplace.
IncompatibleMaterials:Strongacids,strongbases,strongoxidizers.Halogens.Reactivemetals.
Reactivity:Reactsviolentlywithstrongoxidizers.Increasedriskoffireorexplosion.